0.6/1kV XLPE/PVC Insulated Cable
Inquiry >>
If you are interested in 0.6/1kV XLPE/PVC Insulated Cable,Please Feel free to give your inquiry in the form or the email below .We will reply you in 24 hours.
-
JYTOP Cable,professional cable manufacturer
We can produce Bare Conductor(AAC, AAAC, ACSR, ACAR, ACSS...),ABC Cable,xlpe power cable,pvc power cable,Armored Cable(SWA STA),THE cable can according to IEC,ASTM,BS,EN,DIN,VDE,NF,AS/NZS,SABS,SANS,CSA,IRAM… standards and your individual required cables by OEM supply.
-
JYTOP Cable,0.6/1kV PVC insulated Cable Manufacturers and Suppliers,provide 0.6/1kV PVC insulated Cable wholesales,Factory price
-
Rated Voltage(U0/U): 0.6/1kV, 1.9/3.3kV, 3.6/6kV, 3.8/6.6kV, 6/10kV,6.35/11kV, 8.7/15kV, 12/20kV, 12.7/22kV, 18/30kV, 19/33kV, 21/3
-
Application:PVC cable with concentric conductor is used for power transmission on power lines of rated voltage 0.6/1kV or lower. It
-
JYTOP Cable,0.6/1kV XLPE Insulated Cable Manufacturers and Suppliers,provide 0.6/1kV XLPE Insulated Cable wholesales,Factory pri
-
6/10kV XLPE/CWS/PVC Cable
-
50mm armoured cable in India

Application:
0.6/1kV XLPE Cable is used indoor or outdoor, in tunnel, cable furrow or pipe. It able to bear external mechanical forces, but the tractive force during laying.
Standards: IEC60502-1, BS7870-3
Conductor: Cu or Aluminum
Insulation: XLPE (Cross-Linked Polyethylene)
Armor: non-armor, steel tape armored, steel wire armored
Sheath: PVC, Sheath Color: Black or Colors
Product Description:
– XLPE insulated PVC sheathed power cable (XLPE/PVC Cable)
– XLPE insulated steel tape armored PVC sheathed power cable (XLPE/STA/PVC Cable)
– XLPE insulated steel wire armored PVC sheathed power cable (XLPE/SWA/PVC Cable)
– Flame retardant XLPE insulated PVC sheathed power cable (FR/XLPE/PVC Cable)
– Flame retardant XLPE insulated steel tape armored PVC sheathed power cable (FR/XLPE/STA/PVC Cable)
– Flame retardant XLPE insulated steel wire armored PVC sheathed power cable (FR/XLPE/SWA/PVC Cable)
FR – Flame Retardant
Service Conditions And Parameters Of Cable:
The maximum conductor operating temperature: 90℃;
Short Circuit Temperature 250℃Not more than 5 secretary
Environmental Temperature of operating
In air: 40℃, Underground: 25℃
Depth of laying in direct: 80cm
Thermal Resistance of soil: 1.2℃.cm/W
Environment temperature should be no lower than 0℃ for laying the cable.
Cores and Nominal Cross Section Area:
1 core (mm2) |
2 core (mm2) |
3 core (mm2) |
3 core + 1 core (mm2) |
4 core (mm2) |
3 core+ 2 core (mm2) |
4 core + 1 core (mm2) |
5 core (mm2) |
1×4 |
2×4 |
3×4 |
3×4+1×2.5 |
4×4 |
3×4+2×1.5 |
4×4+1×2.5 |
5×2.5 |
1×6 |
2×6 |
3×6 |
3×6+1×4 |
4×6 |
3×6+2×4 |
4×6+1×4 |
5×4 |
1×10 |
2×10 |
3×10 |
3×10+1×6 |
4×10 |
3×10+2×6 |
4×10+1×6 |
5×6 |
1×16 |
2×16 |
3×16 |
3×16+1×10 |
4×16 |
3×16+2×10 |
4×16+1×10 |
5×10 |
1×25 |
2×25 |
3×25 |
3×25+1×16 |
4×25 |
3×25+2×16 |
4×25+1×16 |
5×16 |
1×35 |
2×35 |
3×35 |
3×35+1×16 |
4×35 |
3×35+2×16 |
4×35+1×16 |
5×25 |
1×50 |
2×50 |
3×50 |
3×50+1×25 |
4×50 |
3×50+2×25 |
4×50+1×25 |
5×35 |
1×70 |
2×70 |
3×70 |
3×70+1×35 |
4×70 |
3×70+2×35 |
4×70+1×35 |
5×50 |
1×95 |
2×95 |
3×95 |
3×95+1×50 |
4×95 |
3×95+2×50 |
4×95+1×50 |
5×70 |
1×120 |
2×120 |
3×120 |
3×120+1×70 |
4×120 |
3×120+2×70 |
4×120+1×70 |
5×95 |
1×150 |
2×150 |
3×150 |
3×150+1×70 |
4×150 |
3×150+2×70 |
4×150+1×70 |
|
1×185 |
2×185 |
3×185 |
3×185+1×95 |
4×185 |
3×185+2×95 |
4×185+1×95 |
|
1×240 |
|
3×240 |
3×240+1×120 |
4×240 |
3×240+2×120 |
4×240+1×120 |
|
1×300 |
|
3×300 |
3×300+1×150 |
4×300 |
3×300+2×150 |
|
|
1×400 |
|
|
|
|
|
|
|
1×500 |
|
|
|
|
|
|
|